All the AC contactors have been seen and measured, but how can they be distinguished on a machine? The engineers of cjx2 1810 ac contactor have summed up the following methods for reference.
First, see: A, see whether it works. B, if the contactor is absorbed after the start of the machine, the fan works, the press does not work (the capacitance is good), and the contactor can be judged to be bad. Because both the fan and the press are always controlled by the contactor, the contact work is synchronous. As one of the jobs, the other does not work roughly as the contactor bad
Second, listen: A, listen to whether there is a loud - squeak sound, such as it is (1) power supply voltage is low; (2) the contact point on the dirty material or core hybrid contact surface with dirty substances. If you hear a clicking and clicking sound, most of them are divided into two following cases: (1) low power supply voltage; (2) inadequate contact suction.
Third, smell: smell there is no coke burnt taste, if it please check the winding and contact.
Fourth, measurement: first, disconnect the power, remove the line at the other end of the contact control, then beat it down with multimeter, then press the three main contacts of the test end and the other open contacts. They should all be switched on, and normally closed contacts should not be connected. Put down the end of the test, the main contact and the often open contact should not guide the normally closed contact. The coil value of the coil is about 200 batten. Before measuring, the line at one end should be removed and measured.
Fifth, short circuit: boot, contactor, such as compressor does not turn, you do not know the contact of a contactor is bad, can be used to open the clamp, with two pointed short connection respectively of the same group on contact, so when the compressor work, that bad contact (Note: should Caution! In when you use this method)
How to distinguish the good or bad of an AC contactor
Éditeur : TAIXIRendez-vous amoureux : 2018-01-15Pages vues : 921
LIRE LA SUITE
- Can the electric meter box and the fire hydrant box be a neighbor?
- Effect of voltage protection circuit breaker
- What are the requirements for the wiring when the EPS emergency power supply is used?
- New technology for auto reset circuit breaker with electric energy meter
- Technological innovation and breakthrough of auto reset circuit breaker
- The quality comparison of miniature circuit breakers is carried out in Zhejiang province to promote the quality improvement of the industry
- Communications industry: optical communications maintain a high level of prosperity
- How should consumers choose small circuit breakers?
- Structural characteristics of load isolation switch
- How to ensure the quality of the electric meter box industry
- What is the difference between disconnectors and isolation switches?
- Isolation requirements for electrical isolation switch
- Working principle of DC circuit breaker
- Development of molded case circuit breakers